CHAPTER 5 SYSTEMS: COMMAND AND DATA HANDLING—THE BRAINS OF THE INTERNATIONAL SPACE STATION 96 Table 1. (continued) TIER 3 Connected to Internal Multiplexer/DeMultiplexer Node 1 (N1) Two partially redundant MDMs Both powered on One operating as Primary, one as Secondary Located on PMA-1 Also an connected to C&C MDM Node 1 monitor and control: fire detection and isolation RPCM control Heater control, cabin pressure monitoring Control CBM Recovery of USOS command and control interface (Mighty Mouse) Laboratory-1 Located internal to US Lab Smoke detector monitoring, Common Cabin Air Assembly (CCAA) control, InterModule Ventilation (IMV) control Low Temperature Loop (LTL) temperature control, Loop Crossover Assembly (LCA) valve control, rack flow control Rack power switch monitoring Laboratory-2 Located internal to US Lab Smoke detector monitoring, CCAA control, IMV control Moderate Temperature Loop (MTL) temperature control, LCA valve control, rack flow control Rack power switch monitoring Lab Caution & Warning (C&W) panel control Laboratory-3 Located internal to US Lab Air revitalization, vacuum system control ITCS rack flow control Rack power switch monitoring Airlock Located internal to Airlock Airlock smoke detector monitoring, CCAA, IMV control, depress pump control, Battery Charger Assembly, Umbilical Interface Assembly Node 2 (N2) Located internal to Node 2 Node 2 smoke detector monitoring, CCAA, pressure monitoring, IMV control Node 2 control and monitoring Rack power switch monitoring Node 2 C&W panel control (N2-2 MDM) Japanese Experiment Module C&W panel control (N2-1 MDM) Connected to External Multiplexer/DeMultiplexer S0-1, S0-2 Two partially redundant MDMs Both powered on Operating as bus controller (BC) on different buses Located on S0 Truss Structural Dynamic Measurement System Heat exchanger control, some External Thermal Control System monitoring and Failure Detection, Isolation, and Recovery S0 RPCM control S1-1, S1-2, P1- 1, P1-2 Two partially redundant MDMs Both powered on Operating as BC on different buses Located on S1/P1 Truss Thermal Radiator Rotary Joint control, S1-1/P1-2 MDMs provide primary External Thermal Control System insight, S1-2/P1-1 MDMs provide External Thermal Control System pump commanding S1/P1 RPCM control, S1 MDMs control RPCMs for S1 and Starboard Thermal Radiator MDMs, P1 MDMs control RPCM for P1 MDMs S3-1, S3-2, P3-1, P3-2 Two partially redundant MDMs Both powered on Operating as BC on different buses Located on S3/P3 Truss Solar Array Rotary Joint control, S3/P3 RPCM control, S3 MDMs controls RPCMs for S3 MDMs, P3 MDMs controls RPCMs for P3 MDMs Starboard Thermal Radiator, Port Thermal Radiator Located on S1/P1 Truss Radiator beam insight and commanding (continued next page)
Previous Page Next Page